Loading product details
Preparing specifications, features and applications…
The BR-05A Recirculating Chiller extends the BR-03A's compact precision cooling to an 8L bath format with increased 600W cooling capacity at 10°C — specifically rated for simultaneous cooling of two 2L rotary evaporators or a single 5L unit, making it the practical choice for laboratories running dual rotary evaporation setups or medium-scale solvent recovery. Sharing the BR-03A's full feature platform — PID temperature controller, programmable multi-step control, PT100 sensor, LCD display, preset ON/OFF timing, maintenance-free operation, DIN 12880 compliant independent over-temperature protection, and temperature deviation and over-current alarms — the BR-05A adds the increased tank volume, cooling capacity, and larger 240 × 200 × 170 mm tank opening of the mid-range BR Series format. Enquire about the BR-05A today.


AvailableThe BR-05A Recirculating Chiller delivers 8L of precision -20°C to +20°C coolant circulation with 600W cooling capacity, PID programmable multi-step control, PT100 sensor, independent 6 L/min pump, preset timing, corrosion-resistant stainless steel bath, and DIN 12880 compliant safety — supporting routine laboratory cooling for dual 2L rotary evaporators, single 5L rotary evaporator, chemical processing, and pharmaceutical laboratory applications.
The BR-05A's 8L stainless steel bath provides 60% more coolant volume than the BR-03A's 5L — delivering a proportionally larger thermal mass that buffers temperature fluctuations from variable external heat loads more effectively. In applications where the connected rotary evaporator or chemical process generates variable heat loads (e.g., during solvent changeovers or process startup transients), the larger thermal mass of the BR-05A's 8L bath maintains more stable coolant delivery temperatures than the smaller 5L bath — supporting the ±2°C accuracy specification more consistently across variable load conditions.
The BR-05A's PID controller continuously monitors bath temperature via the PT100 sensor and modulates the R404A compressor and heating outputs to maintain the setpoint with ±2°C accuracy across the full -20°C to +20°C range. The programmable multi-step function enables sequential temperature protocols to be automated — particularly useful in dual rotary evaporator setups where different sequential solvents may require different condenser temperatures, and in pharmaceutical process cooling where defined temperature transitions are protocol requirements.
The BR-05A's 600W cooling capacity at 10°C enables simultaneous condenser cooling for two 2L rotary evaporators — each presenting a condenser heat load of approximately 200–300W at typical evaporation rates. At 0°C setpoint, the 350W capacity supports a single 5L rotary evaporator's condenser requirements. This cooling capacity rating makes the BR-05A the most versatile entry-level BR Series model for multi-instrument laboratory rotary evaporation setups, where a single compact chiller must simultaneously service multiple evaporators.
The BR-05A's 240 × 200 × 170 mm liquid tank opening — larger than the BR-03A's 240 × 150 × 150 mm — accommodates a wider range of direct immersion applications alongside external circulation. The larger opening enables immersion cooling of larger sample containers, reaction vessels, and cold trap assemblies directly in the BR-05A bath — expanding the unit's application versatility beyond external circulation-only use.
The BR-05A's preset ON/OFF timing function enables scheduled chiller start and stop — allowing the unit to pre-cool to the required condenser temperature before the operator's working session begins and to shut down automatically at the end of defined working periods. For laboratory environments running dual rotary evaporator setups with defined morning start times, the preset timing eliminates manual start-up procedures and ensures the coolant is at the required temperature when operation begins.
The BR-05A's maintenance-free design — sealed refrigerant circuit, no oil changes, corrosion-resistant stainless steel construction, and clean surface exterior — minimises the routine maintenance burden in busy routine laboratory environments. Periodic coolant level monitoring through the liquid level viewing window and scheduled coolant replacement at defined intervals constitute the primary routine maintenance requirements, without the mechanical service requirements of more complex cooling system designs.
The BR-05A Recirculating Chiller incorporates temperature deviation alarm, over-current protection, DIN 12880 compliant independent over-temperature protection, and liquid level viewing window — providing the same comprehensive four-system safety architecture as the compact BR-03A, scaled to the 8L mid-range format.
The BR-05A's temperature deviation alarm activates when bath temperature strays beyond the configured threshold — providing early warning of cooling performance issues in dual rotary evaporator setups where a single temperature deviation event simultaneously affects two connected condensers.
Over-current protection monitors the compressor and pump motors and activates protective shutdown if current exceeds safe limits — protecting against compressor overload, pump obstruction, and supply voltage anomalies at 600W total operating power.
DIN 12880 compliant independent over-temperature protection operates entirely separately from the primary PID controller — the critical backup safety circuit for unattended dual rotary evaporator cooling operations where primary controller malfunction must not result in unsafe temperature conditions affecting connected equipment.
The liquid level viewing window provides continuous visual monitoring of the 8L bath coolant level — ensuring operators can verify adequate coolant volume for safe pump and compressor operation during extended dual evaporator cooling sessions.
Explore alternative models and related solutions from other categories