Loading product details
Preparing specifications, features and applications…
The MP-10C Heating and Cooling Recirculating Chiller provides bidirectional temperature control from -10°C to 100°C — combining refrigeration-based cooling and electric heating within a single 4.5L stainless steel bath instrument for precise, stable temperature-controlled fluid circulation to external laboratory equipment. Unlike cooling-only recirculating chillers limited to sub-ambient operation, the MP-10C serves the full range of laboratory temperature control applications from cold-temperature reaction control and condenser cooling through ambient and above-ambient jacketed reactor heating — eliminating the need for separate cooling and heating circulator instruments for laboratories requiring temperature control across the full sub-ambient to elevated temperature range. With LCD microprocessor controller, multi-step programmable operation, 8 L/min built-in circulation pump, stainless steel chamber, 1–5999 minute timer, auto restart after power interruption, and comprehensive safety alarms — the MP-10C provides versatile, precision temperature control for chemical, pharmaceutical, and research external temperature applications.


AvailableThe MP-10C delivers -10°C to 100°C precise heating and cooling recirculation with ±0.2°C precision, LCD microprocessor controller, multi-step programmable settings, 4.5L stainless steel bath, 8 L/min built-in pump, 1–5999 minute timer, maintenance-free design, auto restart, and suitability for external bath applications — providing versatile bidirectional temperature control for chemical, pharmaceutical, and research laboratory applications.
The MP-10C's LCD microprocessor controller provides digital precision temperature management with ±0.2°C accuracy across the full -10°C to 100°C operating range — far more precise and stable than analogue temperature controllers or manual bath temperature management. The microprocessor PID algorithm continuously monitors the actual bath temperature and modulates both the compressor cooling and electrical heating outputs proportionally to maintain the setpoint temperature with ±0.2°C stability — preventing the temperature cycling that compromises reaction temperature control, analytical precision, and material characterisation accuracy in external temperature-controlled laboratory applications.
The MP-10C's programmable controller enables definition of sequential temperature stages with independently specified setpoints and durations — executing automatically in order for complex temperature-time protocols. This multi-step capability is valuable for graduated cooling ramp protocols in crystallisation and precipitation studies, temperature cycling experiments in material characterisation, sequential reactor jacketing programmes in chemical synthesis scale-up, and biological temperature exposure studies requiring defined sequential temperature transitions without manual intervention at each stage transition.
The MP-10C's built-in circulation pump delivers 8 L/min of coolant/heat transfer fluid through the external connection ports — providing the sustained fluid flow required for effective heat transfer at the connected external equipment's heat exchanger or jacketed surface. The 8 L/min flow rate is matched to the connection requirements of standard laboratory rotary evaporators, jacketed reactors, reaction vessels, analytical instrument temperature control inlets, and other external temperature-controlled equipment within the MP-10C's 4.5L compact format.
The MP-10C's 150 × 160 × 150 mm stainless steel bath chamber provides corrosion resistance for the range of heat transfer fluids used across -10°C to 100°C operation — water, glycol/water mixtures, and low-viscosity silicone oils — without the surface degradation or contamination risk of alternative chamber materials. The stainless steel surface enables thorough cleaning between different heat transfer fluid types and supports the hygiene requirements of pharmaceutical and chemical laboratory temperature control applications.
The MP-10C's 1–5999 minute timer enables automated cycle management for defined-duration temperature control applications — chemical reaction temperature programmes, material conditioning cycles, stability testing thermal protocols, and analytical sample temperature equilibration procedures requiring defined timing without continuous operator supervision. Timer automation enables the MP-10C to maintain temperature-controlled conditions for precisely defined periods, automatically completing cycles at the programmed endpoint without operator intervention.
The MP-10C's maintenance-free design minimises the routine servicing burden in busy laboratory environments — eliminating the oil changes, filter replacements, and mechanical service requirements of more complex temperature control systems. The auto restart function automatically restores the MP-10C to its previous operating parameters after power interruption — resuming the programmed temperature setpoint and multi-step programme position without requiring manual operator restart after power outages, ensuring continuous temperature control recovery for extended unattended laboratory temperature applications.
The MP-10C incorporates five independent safety systems — audible and visual temperature and water level alarm, over-temperature protection, sensor failure alarm, power interruption protection with auto restart, and over-current protection — providing comprehensive safe operation for -10°C to 100°C laboratory heating and cooling recirculation.
Dual-mode alarms activate for temperature deviations beyond the configured threshold and for low coolant/heat transfer fluid level in the bath — the two primary operational conditions that compromise temperature control performance and risk pump damage. The audible and visual dual-mode ensures alarm conditions are detected across diverse laboratory environments regardless of ambient noise level or operator proximity to the MP-10C during active temperature control sessions.
The MP-10C's over-temperature protection activates automatic heater cutoff if the bath temperature exceeds the safe upper limit — protecting the heating elements, heat transfer fluid, connected external equipment, and operating personnel from the consequences of uncontrolled heating at temperatures up to 100°C during extended unattended laboratory temperature control operations.
Sensor failure alarm notifies immediately of temperature measurement integrity loss. Power interruption protection combines with auto restart to provide automatic temperature control recovery after power events. Over-current protection safeguards the 2300W compressor and heating system from electrical overload conditions during extended heating and cooling laboratory temperature control operations.
Explore alternative models and related solutions from other categories